/// Passive codec for DLT v1 control services. It never opens a connection or
/// sends requests. Unknown service bodies remain available without interpretation.
/// Per-context services accept -1 to select the configured default (0xff).
/// Services that set the default itself require a concrete level/status.
pub(all) enum ControlRequest {
SetLogLevel(String, String, Int32, String)
SetTraceStatus(String, String, Int32, String)
GetLogInfo(Int32, String, String, String)
GetDefaultLogLevel
StoreConfiguration
ResetConfiguration
SetDefaultLogLevel(Int32, String)
SetDefaultTraceStatus(Int32, String)
GetSoftwareVersion
Unknown(UInt32, Bytes)
} derive(Eq, @debug.Debug)
///|
pub(all) struct ControlResponse {
service_id : UInt32
status : Int32
data : Bytes
} derive(Eq, @debug.Debug)
///|
pub fn ControlRequest::service_id(self : ControlRequest) -> UInt32 {
match self {
SetLogLevel(_, _, _, _) => 1U
SetTraceStatus(_, _, _, _) => 2U
GetLogInfo(_, _, _, _) => 3U
GetDefaultLogLevel => 4U
StoreConfiguration => 5U
ResetConfiguration => 6U
SetDefaultLogLevel(_, _) => 17U
SetDefaultTraceStatus(_, _) => 18U
GetSoftwareVersion => 19U
Unknown(id, _) => id
}
}
///|
fn control_level(value : Int32, trace : Bool) -> Unit raise DltError {
let maximum = if trace { 1 } else { 6 }
guard value >= -1 && value <= maximum else {
raise Invalid(
0, "control log level/trace status is outside its wire domain",
)
}
}
///|
fn control_default_level(value : Int32, trace : Bool) -> Unit raise DltError {
control_level(value, trace)
guard value >= 0 else {
raise Invalid(0, "a default log level/trace status must be concrete")
}
}
///|
fn control_option(value : Int32) -> Unit raise DltError {
guard value >= 3 && value <= 7 else {
raise Invalid(0, "GetLogInfo option must be 3..7")
}
}
///|
fn control_exact(data : BytesView, length : Int32) -> Unit raise DltError {
require_range(data, 0, length)
guard data.length() == length else {
raise Invalid(length, "unexpected trailing control request data")
}
}
///|
fn control_byte(value : Byte) -> Int32 {
if value == b'\xff' {
-1
} else {
value.to_int()
}
}
///|
pub fn encode_control_request(
request : ControlRequest,
endian : Endian,
) -> Bytes raise DltError {
let out = @buffer.Buffer::Buffer()
write_u32(out, request.service_id(), endian)
match request {
SetLogLevel(application, context, level, interface) => {
control_level(level, false)
write_id(out, application)
write_id(out, context)
out.write_byte(level.to_byte())
write_id(out, interface)
}
SetTraceStatus(application, context, status, interface) => {
control_level(status, true)
write_id(out, application)
write_id(out, context)
out.write_byte(status.to_byte())
write_id(out, interface)
}
GetLogInfo(option, application, context, interface) => {
control_option(option)
out.write_byte(option.to_byte())
write_id(out, application)
write_id(out, context)
write_id(out, interface)
}
SetDefaultLogLevel(level, interface) => {
control_default_level(level, false)
out.write_byte(level.to_byte())
write_id(out, interface)
}
SetDefaultTraceStatus(status, interface) => {
control_default_level(status, true)
out.write_byte(status.to_byte())
write_id(out, interface)
}
GetDefaultLogLevel
| StoreConfiguration
| ResetConfiguration
| GetSoftwareVersion => ()
Unknown(id, bytes) => {
guard id != 1U &&
id != 2U &&
id != 3U &&
id != 4U &&
id != 5U &&
id != 6U &&
id != 17U &&
id != 18U &&
id != 19U else {
raise Invalid(
0, "known control service requires its typed request variant",
)
}
guard bytes.length() <= 65531 else {
raise Limit(4, "unknown control request body exceeds wire length")
}
out.write_bytes(bytes[:])
}
}
out.to_bytes()
}
///|
pub fn decode_control_request(
data : BytesView,
endian : Endian,
) -> ControlRequest raise DltError {
guard data.length() <= 65535 else {
raise Limit(0, "control request exceeds wire length")
}
let id = read_u32(data, 0, endian)
match id {
1U => {
control_exact(data, 17)
let application = read_id(data, 4)
let context = read_id(data, 8)
let level = control_byte(data[12])
control_level(level, false)
SetLogLevel(application, context, level, read_id(data, 13))
}
2U => {
control_exact(data, 17)
let application = read_id(data, 4)
let context = read_id(data, 8)
let status = control_byte(data[12])
control_level(status, true)
SetTraceStatus(application, context, status, read_id(data, 13))
}
3U => {
control_exact(data, 17)
let option = data[4].to_int()
control_option(option)
GetLogInfo(option, read_id(data, 5), read_id(data, 9), read_id(data, 13))
}
4U => {
control_exact(data, 4)
GetDefaultLogLevel
}
5U => {
control_exact(data, 4)
StoreConfiguration
}
6U => {
control_exact(data, 4)
ResetConfiguration
}
17U => {
control_exact(data, 9)
let level = control_byte(data[4])
control_default_level(level, false)
SetDefaultLogLevel(level, read_id(data, 5))
}
18U => {
control_exact(data, 9)
let status = control_byte(data[4])
control_default_level(status, true)
SetDefaultTraceStatus(status, read_id(data, 5))
}
19U => {
control_exact(data, 4)
GetSoftwareVersion
}
_ => Unknown(id, data[4:].to_owned())
}
}
///|
/// Generic responses preserve service-specific status values and the full body.
/// GetLogInfo responses use special status values 3..9, so status is not reduced
/// to a success/failure Boolean. Its nested application list is kept raw.
pub fn decode_control_response(
data : BytesView,
endian : Endian,
) -> ControlResponse raise DltError {
require_range(data, 0, 5)
guard data.length() <= 65535 else {
raise Limit(0, "control response exceeds wire length")
}
{
service_id: read_u32(data, 0, endian),
status: data[4].to_int(),
data: data[5:].to_owned(),
}
}
///|
pub fn encode_control_response(
response : ControlResponse,
endian : Endian,
) -> Bytes raise DltError {
guard response.status >= 0 && response.status <= 255 else {
raise Invalid(4, "response status must fit one byte")
}
guard response.data.length() <= 65530 else {
raise Limit(5, "control response body exceeds wire length")
}
let out = @buffer.Buffer::Buffer()
write_u32(out, response.service_id, endian)
out.write_byte(response.status.to_byte())
out.write_bytes(response.data[:])
out.to_bytes()
}
///|
pub fn ControlResponse::software_version(
self : ControlResponse,
endian : Endian,
maximum_bytes~ : Int32 = 65526,
) -> String raise DltError {
guard self.service_id == 19U && self.status == 0 else {
raise Invalid(0, "expected successful GetSoftwareVersion response")
}
guard maximum_bytes >= 0 else {
raise Invalid(0, "negative software version bound")
}
let length = read_u32(self.data[:], 0, endian)
guard length.to_uint64() <= maximum_bytes.to_uint64() else {
raise Limit(9, "software version exceeds configured byte bound")
}
guard length.to_uint64() == (self.data.length() - 4).to_uint64() else {
raise Invalid(5, "software version length does not match response body")
}
let mut end = self.data.length()
if end > 4 && self.data[end - 1] == b'\x00' {
end = end - 1
}
for i in 4.. raise Invalid(9, "software version is not UTF-8")
}
}
///|
pub fn software_version_response(
version : String,
endian : Endian,
) -> ControlResponse raise DltError {
let bytes = encode_text_checked(version, max_bytes=65526)
guard bytes.length() <= 65526 else {
raise Limit(0, "software version exceeds wire length")
}
for b in bytes {
guard b != b'\x00' else {
raise Invalid(0, "software version contains embedded NUL")
}
}
let data = @buffer.Buffer::Buffer()
write_u32(data, bytes.length().reinterpret_as_uint(), endian)
data.write_bytes(bytes[:])
{ service_id: 19U, status: 0, data: data.to_bytes(), }
}
///|
pub fn ControlResponse::default_log_level(
self : ControlResponse,
) -> Int32 raise DltError {
guard self.service_id == 4U && self.status == 0 && self.data.length() == 1 else {
raise Invalid(
0, "expected successful GetDefaultLogLevel response with one byte",
)
}
let level = self.data[0].to_int()
guard level <= 6 else {
raise Invalid(5, "default log level is outside 0..6")
}
level
}
///|
fn require_control(message : Message, subtype : Int32) -> Unit raise DltError {
let extended = match message.header.extended {
Some(value) => value
None => raise Invalid(0, "control message requires extended header")
}
guard !extended.verbose &&
extended.message_type == 3 &&
extended.subtype == subtype else {
raise Invalid(0, "message is not the expected nonverbose control subtype")
}
}
///|
pub fn Message::control_request(
self : Message,
) -> ControlRequest raise DltError {
require_control(self, 1)
decode_control_request(self.payload[:], self.header.endian)
}
///|
pub fn Message::control_response(
self : Message,
) -> ControlResponse raise DltError {
require_control(self, 2)
decode_control_response(self.payload[:], self.header.endian)
}
///|
fn control_header(header : Header, subtype : Int32) -> Header {
let (application, context) = match header.extended {
Some(extended) => (extended.application, extended.context)
None => ("DLTC", "DLTC")
}
{
endian: header.endian,
counter: header.counter,
ecu: header.ecu,
session: header.session,
timestamp: header.timestamp,
extended: Some({
verbose: false,
message_type: 3,
subtype,
argument_count: 1,
application,
context,
}),
}
}
///|
pub fn control_request_message(
request : ControlRequest,
header : Header,
storage? : StorageHeader,
) -> Message raise DltError {
{
storage,
header: control_header(header, 1),
payload: encode_control_request(request, header.endian),
}
}
///|
pub fn control_response_message(
response : ControlResponse,
header : Header,
storage? : StorageHeader,
) -> Message raise DltError {
{
storage,
header: control_header(header, 2),
payload: encode_control_response(response, header.endian),
}
}